Appliance labels list watts, breakers are stamped in amps, and the hydro bill charges for kilowatt-hours. They all describe the same electricity from different angles, and one short formula links them: watts equal volts multiplied by amps. Turn it around and amps equal watts divided by volts.
This post explains the three terms without the jargon, converts watts to amps for loads found in an ordinary Ontario house, and then connects those numbers to the things a homeowner actually deals with: what a breaker is allowed to carry, what shows up on the bill, and when the totals mean a house needs a new circuit or a bigger service.
Volts vs amps: pressure and flow
Voltage is the push. It is the electrical pressure the utility delivers to your meter, and in a house it stays close to fixed. Amperage, measured in amps, is the flow: how much current is moving through a wire at a given moment. A wire and its breaker are sized for flow, which is why breakers carry an amp rating and not a watt rating.
A garden hose is a fair comparison. Water pressure at the tap is roughly constant, while the amount of water moving changes depending on how far you open the nozzle. Plugging in a bigger appliance opens the nozzle wider. The voltage barely moves, but the current rises.
In Ontario the pressure comes in two sizes. Elexicon Energy, for example, supplies its residential customers with single-phase, three-wire power at a nominal 120/240 volts. Standard outlets run at 120 V. Natural Resources Canada describes the 240 V outlet a Level 2 EV charger uses as the same kind a stove or dryer plugs into.
Watts vs amps, or amperage vs wattage
Wattage is the rate at which a device uses energy. It is the number that tells you how hard an appliance works: a 1,500 W heater turns electricity into heat ten times faster than a 150 W one. Amperage only tells you the current, and current on its own does not describe power until you know the voltage behind it.
That is the practical difference between amps vs watts. Two appliances that both draw 10 amps are not equal if one runs at 120 V and the other at 240 V; the second one uses twice the power. When you compare appliances, compare watts. When you ask whether a circuit can handle an appliance, convert to amps, because the wire and breaker care about current.
How to convert watts to amps, and amps to watts
To go from watts to amps, divide the wattage by the voltage of the circuit. To go from amps to watts, multiply the amps by the voltage.
At 120 V, a 600 W load works out to 5 A, and a 1,200 W load to 10 A. At 240 V the same 1,200 W draws only 5 A, because each amp carries twice the voltage. Going the other way, 15 A at 120 V is 1,800 W, and 30 A at 240 V is 7,200 W.
Labels sometimes list kilowatts. One kilowatt is 1,000 watts, so convert first: 7.7 kW is 7,700 W, and 7,700 divided by 240 is about 32 A.
How many watts in an amp?
There is no single answer, because it depends on the voltage. On a 120 V circuit, one amp delivers 120 watts. On a 240 V circuit, one amp delivers 240 watts. That is why the same question can produce two numbers that are both correct.
It also explains why the biggest loads in a house are wired for 240 V. Doubling the voltage halves the current needed for the same wattage: a 4,800 W appliance draws 40 A at 120 V but only 20 A at 240 V.
Have electrical work in mind? Get a free quote.
Licensed & Insured | ECRA/ESA 7014730
Worked examples for common household loads
Portable heater. Natural Resources Canada (NRCan) puts portable heaters in a range of 500 to 1,500 watts and notes they are small enough to plug into regular house circuits. At the top of that range, 1,500 W divided by 120 V is 12.5 A.
Level 1 EV charging. NRCan lists Level 1 charging at 120 V from a standard outlet. Alectra Utilities' EV calculator pairs a 1.4 kW Level 1 charger with a 15 A breaker and a maximum output of 12 A. Check the arithmetic: 12 A times 120 V is 1,440 W, or about 1.4 kW.
Level 2 EV charging. NRCan lists Level 2 charging at 208/240 V. Alectra's calculator pairs a 7.7 kW charger with a 40 A breaker and a 32 A maximum output. At 240 V, 32 A is 7,680 W. A smaller 3.8 kW unit is paired with a 20 A breaker and 16 A of output.
Electric range. In the Electrical Safety Authority's (ESA) worked service calculation for a single house, a range rated up to 12 kW is counted at 6,000 W. Divided by 240 V, that allowance is 25 A of the service.
What the breaker rating allows
A breaker's amp rating is not a target to fill. ESA guidance on luminaire displays states that a 15 amp overcurrent device that is not marked at 100% can only be loaded to a maximum of 12 amps. At 120 V, 12 A is 1,440 W. A single 1,500 W heater at 12.5 A is already above that figure before anything else on the circuit is switched on, and that leaves no room for a lamp or a laptop charger on the same breaker.
Alectra's EV table follows the same pattern for chargers. Each charger's maximum output is four fifths of the breaker it needs: 12 A on a 15 A breaker, 16 A on 20 A, 32 A on 40 A. So when you size a circuit from a label, convert the watts to amps first, then make sure the result fits within what the breaker may carry continuously, not just within the number printed on its handle.
From watts to kWh on your hydro bill
Your bill never mentions amps. The Ontario Energy Board (OEB) explains that your utility measures use in kilowatt-hours, and that one kilowatt-hour is the same as using 1,000 watts for one hour. Its own example is a single 60 W bulb left on for 17 hours.
To estimate what a load costs, multiply its kilowatts by the hours it runs, then by the price. A 1,500 W heater running for four hours uses 6 kWh. At the OEB's Time-of-Use off-peak price of 9.1 cents per kWh, set for November 1, 2026, that is about 55 cents. A 7.68 kW Level 2 charger running for four hours uses about 30.7 kWh, roughly $2.80 at off-peak or $5.81 at the winter on-peak price of 18.9 cents. Those figures cover only the Electricity line of the bill; the OEB sets delivery rates separately, and they appear as their own charges.
The point is that amps decide whether a circuit can carry a load, while watts multiplied by time decide what it costs. A charger that pulls a lot of current for a short window overnight can cost less than a small heater left on all day.
Is 100 amps a lot?
Convert it and see. A 100 A service at 240 V can deliver 24,000 W at once, and a 200 A service 48,000 W. Toronto Hydro says the amperage of a panel should be printed on or near the main breaker, and that most homes have between 100 and 200 amps. Elexicon supplies up to 200 A per dwelling unit on its standard residential service.
Whether 24,000 W is enough depends on what runs at the same time, and the code's method does not count every appliance at its full rating; the range in the example above is counted at 6,000 W even when it is rated for up to 12 kW. ESA's Bulletin 8-3-15 works through a calculation under Rule 8-200 for a single house in which the total calculated load comes to 26,055 W. Divide that by 240 V and you get the bulletin's minimum ampacity of 108.6 A, and after the rule's minimums are applied the required service rating in that example is 125 A. The conversion in this post is the same arithmetic the code calculation finishes with.
When the numbers point to a new circuit or a panel upgrade
A large new load often means a new circuit. If an appliance draws more than a shared 120 V circuit can carry continuously, or it needs 240 V, it gets its own breaker and wire run. The bigger question is whether the panel and service have room for that breaker.
Elexicon's guidance gives a sense of where the line falls. It says a 100 amp panel could serve a mature home with gas heating or a gas stove, or one with mostly older appliances, and that a 200 amp panel is needed if you plan to add air conditioning, a pool, a hot tub or an EV charger. Electric baseboard heat and electric water heating also lean toward 200 amps. Our post comparing 100 and 200 amp panels explains how a load calculation settles that choice for a particular house.
Adding a circuit is electrical work, and ESA requires a notification before it starts. A homeowner may do the work in their own home after filing one, but friends, family and neighbours cannot do it for them, and ESA says handymen cannot do electrical work without an ECRA/ESA licence. As of November 2026, KV Bear Electrical's published range for taking a home from 100 to 200 amps is $2,500 to $5,000, quoted in writing and itemized.
If you have worked out the amps for a new heat pump, charger or hot tub and are not sure the panel can take it, call KV Bear Electrical (ECRA/ESA 7014730) at 905-999-5048 or request a quote.
Frequently Asked Questions
How many amps does a 1,500 watt space heater draw on 120 volts?
About 12.5 amps, since 1,500 divided by 120 is 12.5. ESA guidance says a 15 amp breaker that is not marked for 100% continuous operation can be loaded to a maximum of 12 amps, so a heater that size is best kept off a circuit that is already in use.
Does the hydro bill charge for amps or for watts?
Neither directly. The Ontario Energy Board says utilities measure use in kilowatt-hours, where one kWh equals 1,000 watts used for one hour. Amps matter for sizing wire and breakers, but the bill is based on energy used over time.
How many watts can a 15 amp household circuit carry continuously?
At 120 V, a 15 amp breaker that is not marked for 100% operation is limited to 12 amps by ESA guidance, which is 1,440 watts. Plugged-in loads that run for hours, such as heaters, should be counted against that lower figure.
How many amps does a 7.7 kW Level 2 charger use?
Alectra Utilities' EV calculator lists a maximum output of 32 amps for a 7.7 kW charger and a required 40 amp breaker. At 240 volts, 32 amps works out to 7,680 watts.
Is a 100 amp service enough for a house?
It can be. A 100 amp service at 240 volts supplies 24,000 watts, and Elexicon says a 100 amp panel could serve a mature home with gas heating or mostly older appliances. A load calculation under Rule 8-200 of the Ontario code gives the real answer for a particular home.
Sources
- Elexicon Energy: Residential projects, general information and regulations
- Elexicon Energy: 100 amp vs 200 amp
- Toronto Hydro: Electric heat pumps guide
- Ontario Energy Board: Managing costs with Time-of-Use rates
- Ontario Energy Board: Electricity rates
- ESA SPEC-010 R1: Guidelines for Displays of Luminaires for Sale
- ESA OESC Bulletin 8-3-15: Maximum circuit loading and demand factors
- Alectra Utilities: EV calculator
- Natural Resources Canada: Electric vehicle charging
- Natural Resources Canada: Heating with Electricity
- Electrical Safety Authority: DIY electrical work
- Electrical Safety Authority: Certificate of Acceptance
Facts checked November 26, 2026.
KV Bear Electrical Inc. is a licensed residential electrical contractor (ECRA/ESA 7014730) based in Oshawa, Ontario. The facts here come from the official sources listed above. Have a question about your home? Call 905-999-5048.
Related Services:
Related Guides
Pot Light Installation Cost in Ontario: IC-Rated and Fire-Rated Fixtures Explained
A per-light price only means something once you know the ceiling. This guide walks through what pushes a recessed lighting job up or down, which fixture ratings an insulated or fire-separated ceiling calls for, and the ESA paperwork behind it.
Read the guideAluminum Wiring in Ontario: Years, Warning Signs, Insurance and ESA Repair Rules
When did aluminum branch wiring go into Ontario homes, and why does trouble show up at the connections? Then come what insurers ask for, the device and connector markings ESA Flash 25-18-FL requires, and the paperwork that settles insurance and resale questions.
Read the guideCost to Rewire a House in Ontario: Published Ranges, the Process and Timing
Rewiring a house in Ontario usually starts with knob and tube, aluminum branch wiring, an insurer's request or a renovation. This post covers KV Bear's published ranges for whole-house work, what pushes a quote up or down, the ESA notification and inspections, and what affects the schedule.
Read the guide