Picking a generator starts with a list, not a showroom. The right size depends on which things in your house must keep running when the grid goes down, how much power each one pulls once it is going, and how much extra it needs at the moment it starts. Square footage and the number printed on the box come later.

This post walks through the sizing method generator manufacturers publish, the choice between covering essential circuits and the whole house, how fuel type changes real output, when a portable unit is enough, and the Ontario rules that apply once a generator feeds your home's wiring.

Generator size calculator: running watts plus the biggest starting surge

Every manufacturer's sizing tool, including the online calculators from Generac, Champion and Briggs & Stratton, does the same arithmetic. Running watts are what an appliance draws steadily once it is on. Starting watts, also called surge watts, are the brief extra burst a motor needs to get moving. Lights and phone chargers have no meaningful surge. Fridges, freezers, sump pumps, furnace blowers, well pumps and air conditioners all do.

Generac's guide gives the formula plainly: add up the running wattage of everything you want on at once, then add the single highest starting wattage among those items. Champion sets out the same steps. Only the largest surge is added, because motors rarely all start in the same instant.

Find the numbers on each appliance's nameplate or in its manual. When a label lists only volts and amps, Champion's rule is to multiply them, so a 120 volt motor rated at 6 amps draws about 720 watts. If no starting figure is listed, the brands estimate it differently. Champion puts starting watts at roughly one to two times running watts, while Generac says a motor's surge is often two to three times its running figure. Use the higher multiple when you are unsure.

Here is a worked example using the upper end of Champion's published ranges. A refrigerator at 400 running watts, a freezer at 500, a half horsepower furnace fan at 800, a half horsepower sump pump at 1,050, ten LED bulbs at 15 watts each and 100 watts of chargers come to 3,000 running watts. The sump pump has the largest surge on that list, up to 2,150 starting watts, so the peak need is about 5,150 watts. Briggs & Stratton suggests leaving about 20 percent of headroom for loads you add later, which brings the target to roughly 6,200 watts.

What size generator do I need for my house: essential circuits or the whole home

The answer to "what size generator do I need for my house" turns on one decision: back up only the essentials, or keep the whole house running. Generac sorts appliances into three tiers. The essentials are the fridge and freezer, the internet router, chargers, LED lighting and the sump pump. Comforts such as a microwave or a garage door opener come next. The heavy hitters are central air, an electric range, a well pump, an EV charger and an electric dryer.

Champion's guide says most homes need a 5,000 to 12,500 watt generator to keep essential appliances running. Whole-home coverage works on a different scale. Generac's guide gives 10 to 18 kW for a typical 1,550 square foot house and 20 to 22 kW for 2,000 square feet, but it warns that two homes with the same floor plan can need generators 8 kW or more apart. The heat source matters most. A house with a gas furnace and municipal water asks far less of a generator than one with an electric heat pump and a well pump.

Big motors push the size up quickly. Generac notes that a 3 ton central air conditioner runs on roughly 3.5 to 5 kW but can demand 15 to 18 kW for an instant at start-up. Rather than buying for that spike, Generac and Briggs & Stratton both point to load management, which holds back a lower-priority load while a big one starts, so a smaller unit can cover more of the house. Briggs & Stratton also offers a useful cut-off: when your appliances need more than 8,000 watts, it recommends a standby generator over a portable one.

How fuel type changes a generator's real output

Portable generators usually burn gasoline, and many dual fuel models also take propane. Standby units run on natural gas or propane. The fuel affects more than the refuelling routine. Champion says propane typically delivers about 10 percent less wattage than gasoline, and natural gas about 10 to 15 percent less, so a unit rated on gasoline gives you less on the other two. Check which fuel the rating on the spec sheet refers to before you compare models.

Natural gas means no refills, since the generator draws from the same supply as your furnace. Briggs & Stratton reminds buyers to confirm with the gas utility that its system can support the generator's fuel needs. Propane suits a house with no gas line, but run time then depends on the size of the tank and how much is in it. Gasoline is the easiest to buy and the hardest to store safely. ESA advises letting the engine cool for at least 2 minutes before refuelling and always using fresh gasoline.

Have electrical work in mind? Get a free quote.

Licensed & Insured | ECRA/ESA 7014730

Portable generator for house backup or a home backup generator

A portable generator for house backup is the lower-cost place to start. Champion sells portable units from about 1,000 to more than 22,000 watts, and its 3,000 to 7,000 watt tier is aimed at a fridge, a freezer, a window air conditioner and a TV through an outage. Someone has to be home to wheel the unit out, fuel it, start it and keep it running, often in bad weather.

A home backup generator, usually called a standby generator, sits permanently on a pad outside, draws from the gas or propane supply and is wired to an automatic transfer switch. Champion's standby range runs from about 8,500 to over 26,000 watts, and Generac's air-cooled standby line runs from 10 to 28 kW. When the grid drops, the switch brings the generator on and moves the load across within seconds, whether or not anyone is home. That makes the difference for a well pump, a sump pump during spring thaw, or medical equipment that cannot wait for someone to get home.

Using a generator for power outage backup: Ontario's rules for connecting it

Running appliances on heavy extension cords plugged straight into a portable generator needs no electrician. Feeding the house wiring does. ESA requires a transfer device on any standby generator permanently tied into household wiring, so generator power cannot flow back out into the utility system and energize lines that crews believe are dead. ESA also requires a notification of work before a generator is permanently connected to a home's electrical system, and it strongly recommends hiring a Licensed Electrical Contractor. For a portable unit, the usual arrangement is a manual transfer switch or a panel interlock fed from an outdoor inlet.

So who installs home generators in Ontario? On the electrical side, either the homeowner, after filing a notification with ESA, or a Licensed Electrical Contractor. ESA's DIY page is blunt about the first route: only you can do the electrical work in your own home, and friends, family members or neighbours cannot do it for you. Anyone you pay to do it must hold an ECRA/ESA contractor licence. The gas line to a standby unit is separate work for a licensed gas fitter. The province's own power outage advice is to follow the manufacturer's instructions for a backup generator and to have it professionally installed.

When the work passes, ESA issues a Certificate of Acceptance, which ESA calls an important document for insurance purposes and resale. Keep it with your house papers.

Carbon monoxide: where a portable generator can safely run

A generator engine produces carbon monoxide, which you cannot see or smell. ESA's rule is never to run a generator inside your home or garage, and it notes that fans or open windows and doors will not bring in enough fresh air to keep anyone safe. Ontario's power outage page gives the same warning about generators, barbecues and camping stoves used indoors, because their exhaust can be fatal.

Set a portable unit outside, well away from doors, windows and vents, with the exhaust pointing away from the house. For standby units, Briggs & Stratton's installation guidance calls for a spot at least five feet from any opening in the home, with the exhaust aimed away from windows and doors, and your installer follows the clearances in that model's manual. Ontario also recommends battery-operated smoke and carbon monoxide alarms as part of getting ready for an outage.

ESA adds two cautions for cords and wet equipment. Use grounded three-prong extension cords rated for the load, uncoiled and laid flat, since coiled cords can get extremely hot. Never connect a portable generator to appliances or wiring that water has damaged.

What a home backup generator costs to install

Generac's own guide cautions that the price of the unit is only the starting point. Installation, permits, a concrete pad, the gas line or propane tank, and the electrical work all add to the total. For a complete standby job, KV Bear Electrical publishes a range of $8,000 to $18,000 (as of November 2026), which takes in the generator, the transfer switch, the electrical work and the permit. The size of the generator and how involved the installation is decide where a home lands in that range.

Bring your appliance list and nameplate numbers to the quote, since they make the load calculation faster and keep the size honest. To have a standby generator, or a transfer switch for a portable unit, sized and installed by a licensed contractor (ECRA/ESA 7014730), call KV Bear Electrical at 905-999-5048 or request a quote.

Frequently Asked Questions

How do I work out a generator's starting watts if the label only lists amps?

Multiply volts by amps for the running watts, which is Champion's method: a 120 volt appliance drawing 6 amps uses about 720 watts. For the surge, Champion estimates one to two times the running figure and Generac two to three times for motors. Use the higher multiple for pumps and compressors unless the manual gives a starting number.

Does a natural gas generator produce less power than a gasoline one?

Usually, yes. Champion says natural gas typically delivers about 10 to 15 percent less wattage than gasoline, and propane about 10 percent less. Check which fuel a spec sheet's rating is based on, and size from the figure for the fuel you will actually use.

Can I size a standby generator from my home's square footage?

Only as a rough starting point. Generac's ranges run from 10 to 18 kW for about 1,550 square feet up to 20 to 22 kW for 2,000 square feet, but it warns that two homes with the same floor plan can differ by 8 kW or more. Heat pumps, well pumps and central air move the number most, so a load calculation should set the final size.

Who installs home generators in Ontario?

A Licensed Electrical Contractor makes the electrical connection and files the ESA notification, or a homeowner may do the work on their own home after notifying ESA. Friends, relatives and neighbours cannot do it for you. The gas or propane connection for a standby unit is done by a licensed gas fitter.

Is a portable generator enough to get through a power outage?

For essentials over a short outage, often yes. Champion aims its 3,000 to 7,000 watt portable units at a fridge, freezer, window air conditioner and TV. Someone has to run it outdoors and keep it fuelled, and once it feeds the house wiring rather than extension cords, it needs a transfer switch or interlock and an ESA notification.

Published by KV Bear Electrical

KV Bear Electrical Inc. is a licensed residential electrical contractor (ECRA/ESA 7014730) based in Oshawa, Ontario. The facts here come from the official sources listed above. Have a question about your home? Call 905-999-5048.

Have a Question? Get a Free Quote

ECRA/ESA 7014730 | Licensed & Insured

Get Your Free Quote Today

Prefer to talk? Call us.

By submitting this form, you agree to receive email from KV Bear Electrical about your request. You can ask us to stop at any time.