# Aluminum Wiring Repair in Scarborough | KV Bear Electrical

URL: https://kvbearelectrical.ca/electricians-in-scarborough/aluminum-wiring

> Aluminum wiring in 1960s and 1970s Scarborough homes: assessment, copper pigtailing or full replacement, with ESA inspection. Licensed ECRA/ESA 7014730.

Scarborough, Greater Toronto Area

# Aluminum Wiring Repair and Replacement in Scarborough

KV Bear Electrical is a licensed electrical contractor (ECRA/ESA 7014730) based in Oshawa that does residential work in [Scarborough](https://kvbearelectrical.ca/electricians-in-scarborough) , including our [aluminum wiring service](https://kvbearelectrical.ca/services/aluminum-wiring) for homes there.

Get a Free Quote [Call 905-999-5048](tel:+19059995048)

Licensed & Insured

ECRA/ESA 7014730

Electrical Safety Authority of Ontario

[Rated 5/5 on HomeStars](https://homestars.com/companies/2953020-kv-bear-electrical-inc)

as of October 2026

## Get an Aluminum Wiring Quote in Scarborough

## Aluminum Wiring in Scarborough's 1960s and 1970s Houses

Much of Scarborough was built in the same years that aluminum branch wiring was going into Ontario homes. The City of Toronto's 2021 profile of the Scarborough Community Council area puts 36.9% of its dwellings in the 1961 to 1980 period. That is the largest single group, and well above the citywide 28.8%. ESA says homes built from the mid-1960s to the late 1970s may have aluminum wiring, so plenty of houses in Agincourt, Malvern and the streets in between deserve a look.

Having aluminum wiring does not make a house dangerous by default. ESA's view is that it can be safe when it is connected and terminated with devices approved for aluminum. Trouble shows up at the connections: a receptacle replaced with a copper-only device, a push-in outlet, or an aluminum-to-copper splice made with the wrong connector. An assessment looks at exactly those points, and they are what an insurer is likely to ask about.

## What Scarborough Homeowners Should Know

- The Electrical Safety Authority says homes built from the mid-1960s to the late 1970s may have aluminum wiring, and recommends hiring a Licensed Electrical Contractor experienced with aluminum wiring to assess the system, make repairs and have ESA inspect the work. It notes that insurers are increasingly refusing or non-renewing coverage unless the wiring is inspected, and in some cases require replacement with copper.

    [Source: Aluminum Wiring, Electrical Safety Authority (esasafe.com)](https://esasafe.com/home-renovation-buying-and-selling/aluminum-wiring/)
- The City of Toronto's 2021 ward profile for Scarborough-Agincourt shows 18,390 of the ward's private dwellings, 48.0%, were built between 1961 and 1980, compared with 28.8% for Toronto as a whole.

    [Source: Ward Profile: Scarborough-Agincourt (2021 Census), City of Toronto (toronto.ca)](https://www.toronto.ca/wp-content/uploads/2024/01/8cca-CityPlanning-2021-Census-Profile-Ward-22.pdf)
- In the Scarborough North ward, 39.3% of the 29,545 dwellings counted in the City's 2021 ward profile were built between 1961 and 1980, the ward's largest construction period.

    [Source: Ward Profile: Scarborough North (2021 Census), City of Toronto (toronto.ca)](https://www.toronto.ca/wp-content/uploads/2024/01/93f4-CityPlanning-2021-Census-Profile-Ward-23.pdf)
- A 2026 City of Toronto planning report on 27, 31 and 51 Tapscott Road, the site of Malvern Town Centre, lists the property in Ward 23, Scarborough North.

    [Source: 27, 31 and 51 Tapscott Road report, City of Toronto (2026) (toronto.ca)](https://www.toronto.ca/legdocs/mmis/2026/cc/bgrd/backgroundfile-289655.pdf)
- ESA Flash 25-18-FL (May 2025) says devices with push-in terminations shall not be used with aluminum conductors, that switches and receptacles rated 20 amps or less must carry an aluminum-rated marking such as CO/ALR, and that wire connectors must be marked for joining aluminum and copper conductors.

    [Source: Flash 25-18-FL: Aluminum wiring in residential installations, Electrical Safety Authority (esasafe.com)](https://esasafe.com/assets/files/esasafe/pdf/Electrical_Safety_Products/Flash_Notices/25-18-FL.pdf)
- Toronto Hydro's metering requirements for services of 750 volts or less (as of January 1, 2026) require a proper bi-metallic connector wherever a connection is made between aluminum and copper conductors.

    [Source: Reference 6: Metering Requirements 750 Volts or Less, Toronto Hydro (torontohydro.com)](https://www.torontohydro.com/documents/d/guest/ref-6-metering-requirements-750-volts-or-less-as-of-jan-1-2026)

Facts checked October 13, 2026.

## What an Aluminum Wiring Electrician Checks in a Scarborough House

The ward profiles show how much of Scarborough falls inside ESA's window. In Scarborough-Agincourt, 48.0% of private dwellings went up between 1961 and 1980. In Scarborough North, the ward that takes in the Malvern Town Centre site, the same period accounts for 39.3% of its 29,545 dwellings, more than any other. Owners of those houses, and people buying them, are who this assessment is for.

Afterward you get a written summary of what we found, with each possible approach priced.

1. 1

    ### Panel first

    The cable markings and breakers there show which circuits are aluminum.

2. 2

    ### A sample of boxes

    Receptacles, switches and fixture boxes around the house are opened to look for copper-only devices, push-in connections, discolouration and splices made with unmarked connectors.

3. 3

    ### Additions and basements

    These get a closer look, since newer copper circuits from later work can meet the original aluminum there.

4. 4

    ### The service entrance

    Toronto Hydro's metering rules call for a proper bi-metallic connector at any joint between aluminum and copper.

## Aluminum Wiring Replacement in Scarborough: Our Prices and Credentials

In a typical three-bedroom Ontario home, our published ranges are $2,000 to $4,500 to pigtail and $8,000 to $15,000 or more to replace the aluminum with copper. The itemized quote you get after the Scarborough assessment confirms the figure for your house.

Get a Free Quote [Call 905-999-5048](tel:+19059995048)

If a 200 amp upgrade is already on your list, plan it with the remediation and the panel work only happens once. We look at both together when we quote.

- ESA licence 7014730 (ECRA/ESA), searchable by anyone on the Contractor Locator Tool.
- Each approach we price is broken into line items, and nothing starts until you have it in writing.
- We submit the ESA notification before work begins, and you get the Certificate of Acceptance your insurer is likely to ask for.
- Calls are booked weekdays from 7am to 6pm and Saturdays from 8am to 2pm, with urgent work given priority in that window.

[Check our licence on ESA's Contractor Locator](https://licensing.esasafe.com/contractor-locator-tool/)

## Scarborough Aluminum Wiring: What Our Reviews and Ratings Show

We publish our customer reviews in full on Housecall Pro, and the cards below come from there, one of them about aluminum remediation. Outside our own page, HomeStars rates KV Bear Electrical 5 out of 5 (checked October 2026) and the BBB lists a company profile in Oshawa.

[Housecall Pro reviews](https://client.housecallpro.com/reviews/widget/8327d3db-3ca2-4c89-83bc-01ad9344901b) [HomeStars](https://homestars.com/companies/2953020-kv-bear-electrical-inc) [BBB](https://www.bbb.org/ca/on/oshawa/profile/electrician/kv-bear-electrical-inc-0107-1407313)

> “Kyle did an excellent job with the aluminum wiring remediation on my home and installing external pot lights. The work is high-quality and the new lights look great. Highly recommend his services!”

Sandy A.

[Review on Housecall Pro](https://client.housecallpro.com/reviews/widget/8327d3db-3ca2-4c89-83bc-01ad9344901b) · October 2026

> “Kyle has done a lot of electrical work at my home over the last couple of years, from upgrading my electrical panel to fixing my smart thermostats. He is friendly, highly professional, and genuinely cares about what’s best for his customers. I would recommend him to anyone looking to get electrical work done.”

Anuraag S.

[Review on Housecall Pro](https://client.housecallpro.com/reviews/widget/8327d3db-3ca2-4c89-83bc-01ad9344901b) · October 2026

> “Kyle is super professional, on time, fair with pricing and keeps you informed the whole way. Highly recommend them!”

Kristen T.

[Review on Housecall Pro](https://client.housecallpro.com/reviews/widget/8327d3db-3ca2-4c89-83bc-01ad9344901b) · October 2026

## Pigtailing or Aluminum Wiring Replacement in Scarborough

With pigtailing, the aluminum branch circuits stay in the walls and only the connection points change. At each one, a short copper lead is joined to the aluminum conductor using a connector approved for that pairing, and the device is wired to the copper. That goes for every receptacle, switch, light and junction box in the house. ESA's flash notice describes this method for connecting copper-only devices to aluminum, and it means far less disruption than opening walls. ESA's view is that aluminum wiring can be safe when it is connected with devices approved for it.

Aluminum wiring replacement takes the aluminum circuits out and runs new copper cable. It costs more, and there is patching afterward. It also settles the question for good, which makes it the obvious pick when the house is being gutted for a renovation or the insurer insists on copper.

### Pigtail every point or rewire

Pigtails keep plaster intact and cost less, while new copper cable costs more, leaves patching and ends the matter.

### Fix before listing or under deadline

Sorting it out ahead of a sale beats a rushed repair written into a sale condition.

### Owner notification or experienced contractor

ESA permits owner work after filing, but bans push-in devices on aluminum and recommends a contractor who knows the metal.

## Insurance, Selling and Your Scarborough Wiring

ESA notes that insurers are increasingly refusing or non-renewing coverage unless aluminum wiring is inspected, and that some ask for copper. Whichever route you choose, the Licensed Electrical Contractor files the ESA notification before work starts and ESA inspects the finished job. The ESA Certificate of Acceptance that follows is the documentation your insurer is likely to want, and paperwork showing the work was inspected also answers a buyer's questions directly. To book an assessment of the wiring in your Scarborough home, call [905-999-5048](tel:+19059995048) or request a quote below.

## Aluminum Wiring in Scarborough: Common Questions

Is my 1970s Scarborough house likely to have aluminum wiring?

It's possible. ESA says homes built from the mid-1960s to the late 1970s may have it, and a big share of Scarborough's housing dates from that stretch. To know for sure, have the panel checked first, since the cable markings there show the conductor type, and then the circuits around the house.

Do I have to replace all the aluminum wiring in my Scarborough home?

Usually not. ESA's position is that aluminum wiring can be safe when it is connected with devices approved for aluminum, and pigtailing does exactly that. Replacement makes more sense if your insurer insists on copper, if the walls are already open for a renovation, or if the assessment turns up damaged conductors.

Can I change the outlets myself in a house with aluminum wiring?

ESA allows homeowners to do electrical work in their own home once they file a notification, but aluminum connections leave little room for error. ESA's flash notice bans push-in devices on aluminum and requires aluminum-rated devices or proper copper pigtails, so a standard copper-only receptacle won't do on its own. That is why ESA recommends a contractor experienced with aluminum.

Will aluminum wiring come up when I sell a house in Agincourt or Malvern?

It can. The buyer's home inspector may flag it, and the buyer's insurer may ask about it before closing. If the remediation is done and the ESA Certificate of Acceptance is on file, you can answer with documents instead of estimates.

## Guides on Aluminum Wiring

[Buying & Selling Homes ### Should You Get an Electrical Inspection Before Selling Your Home? We found no Ontario rule that makes a seller get an electrical inspection, but buyers are told to verify open permits with ESA, so a pre-listing check can catch problems first. Read the guide](https://kvbearelectrical.ca/blog/home-electrical-inspection-before-sale) [Electrical Safety ### Lights Flickering in the House? How to Find the Cause One flickering lamp usually comes down to the bulb or its dimmer. Lights flickering across several rooms point further back, to a connection, the service or the utility. The pattern tells you whether to call an electrician or the utility. Read the guide](https://kvbearelectrical.ca/blog/flickering-lights-in-house) [Wiring & Rewiring ### Knob and Tube Wiring in Ontario: Code Status, Risks, Assessment and Replacement A homeowner's guide to knob and tube wiring in Ontario: the years it was installed, why the 2021 Code did not force removal, the hazards ESA and Natural Resources Canada describe, and how an assessment and a phased rewire work. Read the guide](https://kvbearelectrical.ca/guides/knob-and-tube-wiring-ontario)

### Aluminum Wiring in Nearby Areas

- [Aluminum Wiring in Toronto](https://kvbearelectrical.ca/electricians-in-toronto/aluminum-wiring)
- [Aluminum Wiring in North York](https://kvbearelectrical.ca/electricians-in-north-york/aluminum-wiring)
- [Aluminum Wiring in Whitby](https://kvbearelectrical.ca/aluminum-wiring-replacement-in-whitby-durham-region)
- [Aluminum Wiring in Etobicoke](https://kvbearelectrical.ca/electricians-in-etobicoke/aluminum-wiring)

### Other Services in Scarborough

- [EV Charger Installation in Scarborough](https://kvbearelectrical.ca/electricians-in-scarborough/ev-charger-installation)
- [Panel Upgrade in Scarborough](https://kvbearelectrical.ca/electricians-in-scarborough/panel-upgrade)
- [Pot Light Installation in Scarborough](https://kvbearelectrical.ca/electricians-in-scarborough/pot-light-installation)
- [Knob & Tube Wiring in Scarborough](https://kvbearelectrical.ca/electricians-in-scarborough/knob-and-tube-wiring)

[More about our aluminum wiring service →](https://kvbearelectrical.ca/services/aluminum-wiring) [All electrical services in Scarborough →](https://kvbearelectrical.ca/electricians-in-scarborough)

## Need Aluminum Wiring in Scarborough? Call Us for a Free Quote.

Licensed & Insured | ECRA/ESA 7014730

[Call 905-999-5048](tel:+19059995048) [Get a Free Quote](https://kvbearelectrical.ca/estimate)

## Get a Free Aluminum Wiring Quote in Scarborough

ECRA/ESA 7014730 | Licensed & Insured

### Get Your Free Quote Today
